Legionella Compliance

MP-HOT Hot Water Chlorine Analyzer

24-hour Legionella compliance monitoring directly in building hot water loops. Measures chlorine, pH, conductivity, and temperature — all in-pipe with no waste stream.

Free ChlorinepHConductivityTemperature
verifiedNSF-61
gavelASHRAE 188
medical_servicesCDC Guidelines
MP-HOT Hot Water Chlorine Analyzer

Meets ASHRAE Standard 188, CDC guidelines, and New Jersey SB2188 requirements for Legionella water management plans. 24-hour continuous monitoring replaces manual grab samples.

Key Benefits

verified

Direct In-Pipe (NSF-61)

Install directly into hot water return loops. No bypass panels, no sample lines, no floor drains required.

water_drop

No Waste Stream

Eliminates 70,000 gallons of wasted water per year. Saves $490 in water costs and $950 in energy costs annually.

hub

Monochloramine Option

Available with monochloramine measurement for facilities using chloramine-based disinfection systems.

dashboard

4 ASHRAE/CDC Parameters

Measures all parameters required by ASHRAE 188 and CDC water management plans in a single probe.

schedule

24-Hour Compliance Monitoring

Continuous data replaces weekly grab samples. Captures transient events that manual testing misses 99.9% of the time.

Learn More →

Self-Cleaning (SensiCLENE)

Polymer bead cleaning system prevents scaling in hot water environments. 6-12 months maintenance-free operation.

Where MP-HOT is Deployed

Protecting building occupants from Legionella in the facilities that need it most.

local_hospital

Hospitals & Healthcare Facilities

Protect immunocompromised patients with continuous Legionella monitoring. Meet Joint Commission and CMS requirements.

hotel

Hotels & Hospitality

Automated compliance monitoring across large plumbing systems. Reduce liability and protect guests from waterborne pathogens.

apartment

Commercial Office Buildings

Meet ASHRAE 188 water management plan requirements. Continuous verification without dedicated maintenance staff.

Technical Specifications

SpecificationValue
Measurement Range0 – 10 mg/L Free Chlorine
Accuracy± 5% of reading or 0.02 mg/L
Temperature Range2°C to 50°C (35.6°F to 122°F)
Pressure Range0 – 100 psi (6.9 bar)
Flow Range0.1 to 10 ft/s (flow independent)
pH Range2 – 12 pH
ConnectivityBluetooth, Modbus RTU/TCP, BACnet
Calibration Interval6 Months (standard)
Maintenance Interval12 Months (wear parts swap)
CertificationsNSF/ANSI 61, ASHRAE 188 compliant

Download the MP-HOT Data Sheet

Get full technical specs, wiring diagrams, compliance documentation, and dimensional drawings.

Protect your building. Meet compliance requirements.